SL-176 True Double Beam AAS

ELICO’s SL- 176, AAS Spectrophotometer comes with semi-automated gas control system and delivers a new level of flexibility and simplicity. It can work as standalone mode for routine analysis and can also be PC Controlled

 

 

 

 

 

 

 

 

SALIENT FEATURES 

  • Microprocessor and Microcontroller based user friendly, Menu driven with printer interface and optional PC attachment through USB Interface
  • High Energy True Double Beam Optics with Narrow Beam, fully sealed and Quartz over coated mirrors
  • 6 lamp turret with independent power supplies for warm-up
  • Background correction with D2 lamp source
  • Integral gas control system with panel flow meters
  • Precise Knobs for Vertical, Horizontal and Rotational alignment of Titanium Burner
  • Modes of operation include Absorbance, Emission, Concentration and Standard Addition
  • Optional : 21 CFR Part 11 PC Software, Auto Sampler, Hydride and Cold Vapour Generator

    คุณสมบัติเด่น

        -ควบคุมการทำงานด้วยระบบไมโครโปรเซสเซอร์และระบบไมโครคอนโทรลเลอร์ ใช้งานง่าย มีเมนูเชื่อมต่อกับเครื่องพิมพ์ และ        option การเชื่อมต่อกับ PC ผ่านสาย USB
        -ระบบ Optics เป็นแบบลำแสงคู่ (Double Beam)ชนิดพลังงานสูง มีลำแสงที่แคบ ปิดผนึกอย่างเต็มที่
       -บรรจุแหล่งกำเนิดแสง 6  หลอดพร้อมแหล่งจ่ายไฟแยกอิสระสำหรับอุ่นไส้หลอด

        -การแก้ไขสัญญานพื้นหลัง (Background Correction)ด้วยแหล่งกำเนิดแสง D2 lamp
       -ประกอบด้วยระบบควบคุมแก๊สและแผงวัดอัตราการการไหล
       -มีลูกบิดที่แม่นยำสำหรับการปรับ Alignment ทางแนวตั้ง แนวนอนและการหมุนของหัว Burner  ชนิดไทเทเนียม
       -โหมดการทำงาน ประกอบด้วย โหมดการวัดการดูดกลืนแสง (Absorbance) , วัดการเปล่งแสง (Emission)  ,วัดความเข้มข้น           (Concentration)และ Standard Addition
        -มีตัวเลือก (option): 21  CFR Part 11 , Auto Sampler, Hydride และ Cold Vapor Generator
 
 
 
TECHNICAL SPECIFICATIONS
 
SPECTRAL 
Range185 to 900 nm
BandwidthAutomatic variable slit from 0 to 2.5 nm continuously variable with increment of 0.1 nm
Readability0.1 nm
Accuracy± 0.5 nm
Repeatability± 0.2 nm
PHOTOMETRIC 
Range0 to 2 Abs
Accuracy± 0.010 Abs at 1.0 Abs
Integration Time0.04 to 99 sec
LIGHT SOURCE
6 Lamps Automatic Turret with Independent Power Supply compatible to coded and non coded HC Lamps.
MONOCHROMATOR
Czerney Turner 1/3 m with 1800 lines/mm Holographic Grating and Hard Coded Optics.
BACK GROUND CORRECTION
Deuterium Lamp (D2)
BURNER
Titanium construction, Premix Laminar Flow100mm burner for Air – Acetylene (C2H2)
Optional – 50 mm burner for Nitrous Oxide (N2O) – 2 Acetylene (C2H2)
The Spray Chamber is made of Inert Material .i.e., PTFE (Teflon) fitted with adjustable impact bead Aerosol
NEUBULIZER
Made of fully Inert Material with 90% Platinum and 10% Iridium Alloy Capillary
SAMPLE FEED RATE3 to 8 ml/min (Adjustable)
DETECTOR
Wide Range Photo Multiplier Tube (PMT)
FLOW CONTROL
Integral Gas Control System with Panel Flow Meters
SYSTEM UPGRADATION
Instrument can be upgraded to Auto Sampler, Hydride and Cold vapour Generator
ACCESSORIES SUPPLIED 
With Instrument100 mm burner for Air – C2H2 , Nebulizer with SS Capillary, Back Ground Correction with DLamp, Oil free Air Compressor with 100% Dustfree Air Filter, Acetylene (C2H2) regulator with Flashback Arrester.
At extra Cost50 mm burner for N2O2 – C2H2 , Nebulizer with Pt – Ir Capillary, N2O Regulator, Nitrogen Regulator, HC Lamps for desired Elements coded or non coded, Hydride and Cold vapour Generator, Printer, Computer, PC Software, Exhaust Fumehood Chamber, Servo Controlled Voltage Stabilizer of suitable rating, Acetylene Gas Cylinder, Nitrous Oxide Gas Cylinder and Nitrogen Gas Cylinder.

 

SL176 Brochure